Knygos.lt klubas Knygos.lt nariams
20,29 €
-30%
Įprastai
28,99 €
NIST Technical Note 1452
NIST Technical Note 1452
Knygos.lt klubas Knygos.lt nariams
20,29 €
-30%
Įprastai
28,99 €
  • Išsiųsime per 12–18 d.d.
This research investigates the stability of iodotrifluoromethane (CF3I) during storage. For CF3I to be used as a fire extinguishing agent, it must be able to be stored for long periods of time at high pressure in metal containers without degrading and losing its effectiveness. For these experiments, CF3I was placed into cylinders, along with various metal coupons. The cylinders were stored, some at elevated temperatures in an oven, for three years and then placed into storage at ambient tempera…

NIST Technical Note 1452 (el. knyga) (skaityta knyga) | knygos.lt

Atsiliepimai

Aprašymas

This research investigates the stability of iodotrifluoromethane (CF3I) during storage. For CF3I to be used as a fire extinguishing agent, it must be able to be stored for long periods of time at high pressure in metal containers without degrading and losing its effectiveness. For these experiments, CF3I was placed into cylinders, along with various metal coupons. The cylinders were stored, some at elevated temperatures in an oven, for three years and then placed into storage at ambient temperature for five more years. Infrared spectroscopy was used to analyze the cylinder contents and concentrations at various times during the storage.

Knygos.lt klubas
Knygos.lt nariams
20,29 €
-30%
Įprastai
28,99 €
Kaina registruotiems pirkėjams
Prisijunkite ir už šią prekę
gausite 0,29 Knygų Eurų!?
Išsiųsime per 12–18 d.d.
Įsigykite dovanų kuponą
Daugiau

This research investigates the stability of iodotrifluoromethane (CF3I) during storage. For CF3I to be used as a fire extinguishing agent, it must be able to be stored for long periods of time at high pressure in metal containers without degrading and losing its effectiveness. For these experiments, CF3I was placed into cylinders, along with various metal coupons. The cylinders were stored, some at elevated temperatures in an oven, for three years and then placed into storage at ambient temperature for five more years. Infrared spectroscopy was used to analyze the cylinder contents and concentrations at various times during the storage.

Atsiliepimai

  • Atsiliepimų nėra
0 pirkėjai įvertino šią prekę.
5
0%
4
0%
3
0%
2
0%
1
0%
(rodomas nebus)
[{"option":"222","probability":1,"style":{"backgroundColor":"#ffffff"},"image":{"uri":"\/uploads\/images\/wheel_of_fortune\/6a3ba631ba76d1782294065.png","sizeMultiplier":0.6,"landscape":true,"offsetX":-50}},{"option":"221","probability":1.3,"style":{"backgroundColor":"#e1032e"},"image":{"uri":"\/uploads\/images\/wheel_of_fortune\/6a3ba61ea9f381782294046.png","sizeMultiplier":0.6,"landscape":true,"offsetX":-50}},{"option":"220","probability":1.6,"style":{"backgroundColor":"#ffffff"},"image":{"uri":"\/uploads\/images\/wheel_of_fortune\/6a3ba60167d251782294017.png","sizeMultiplier":0.6,"landscape":true,"offsetX":-50}},{"option":"219","probability":1.5,"style":{"backgroundColor":"#e2022e"},"image":{"uri":"\/uploads\/images\/wheel_of_fortune\/6a3ba5ea1c47d1782293994.png","sizeMultiplier":0.6,"landscape":true,"offsetX":-50}},{"option":"218","probability":1.5,"style":{"backgroundColor":"#ffffff"},"image":{"uri":"\/uploads\/images\/wheel_of_fortune\/6a3ba5d38b4a21782293971.png","sizeMultiplier":0.6,"landscape":true,"offsetX":-50}},{"option":"217","probability":1.6,"style":{"backgroundColor":"#e3022e"},"image":{"uri":"\/uploads\/images\/wheel_of_fortune\/6a3ba5b981b7a1782293945.png","sizeMultiplier":0.6,"landscape":true,"offsetX":-50}},{"option":"216","probability":1.4,"style":{"backgroundColor":"#ffffff"},"image":{"uri":"\/uploads\/images\/wheel_of_fortune\/6a3ba58b535551782293899.png","sizeMultiplier":0.6,"landscape":true,"offsetX":-50}},{"option":"215","probability":0.1,"style":{"backgroundColor":"#ffe01a"},"image":{"uri":"\/uploads\/images\/wheel_of_fortune\/6a3ba53a6496f1782293818.png","sizeMultiplier":0.6,"landscape":true,"offsetX":-50}}]