Knygos.lt klubas Knygos.lt nariams
70,76 €
-30%
Įprastai
101,09 €
Development of Mixed Refrigerant Cascade Freezer
Development of Mixed Refrigerant Cascade Freezer
Knygos.lt klubas Knygos.lt nariams
70,76 €
-30%
Įprastai
101,09 €
  • Išsiųsime per 12–18 d.d.
A large number of new application in biology, biotechnology etc. requires preservation of cells, tissues etc. at temperature down to 173K. So there is a worldwide attention to develop the system to meet this temperature.Conventional cascade vapour compression refrigerators are normally used for providing refrigeration below 230K. Generally, two cascade stages are required for temperatures down to 200K and three stages for temperatures down to 173K. As the number of stages increase, the complexi…
  • Leidėjas:
  • Metai: 2015
  • Puslapiai: 52
  • ISBN-10: 3639859596
  • ISBN-13: 9783639859591
  • Formatas: 15.2 x 22.9 x 0.3 cm, minkšti viršeliai
  • Kalba: Anglų

Development of Mixed Refrigerant Cascade Freezer (el. knyga) (skaityta knyga) | knygos.lt

Atsiliepimai

Aprašymas

A large number of new application in biology, biotechnology etc. requires preservation of cells, tissues etc. at temperature down to 173K. So there is a worldwide attention to develop the system to meet this temperature.Conventional cascade vapour compression refrigerators are normally used for providing refrigeration below 230K. Generally, two cascade stages are required for temperatures down to 200K and three stages for temperatures down to 173K. As the number of stages increase, the complexity of the system, number of heat exchangers and compressors, and ultimately cost increases. Alternatively, it is also possible to use single stage refrigeration system that operates with a mixture of refrigerants to provide refrigeration at low temperatures. Such systems are known as Mixed Refrigerant Cascade (MRC) systems, or Auto Refrigerant Cascade (ARC)system.The use of a single compressor (used in domestic refrigerators and air conditioners) in a MRC refrigeration system compared to multiple compressors in cascade vapour compression refrigerator results in reduction of cost and complexity, and increases reliability.

Knygos.lt klubas
Knygos.lt nariams
70,76 €
-30%
Įprastai
101,09 €
Kaina registruotiems pirkėjams
Prisijunkite ir už šią prekę
gausite 1,01 Knygų Eurų!?
Išsiųsime per 12–18 d.d.
Įsigykite dovanų kuponą
Daugiau
  • Autorius: Ratre Kamlesh
  • Leidėjas:
  • Metai: 2015
  • Puslapiai: 52
  • ISBN-10: 3639859596
  • ISBN-13: 9783639859591
  • Formatas: 15.2 x 22.9 x 0.3 cm, minkšti viršeliai
  • Kalba: Anglų

A large number of new application in biology, biotechnology etc. requires preservation of cells, tissues etc. at temperature down to 173K. So there is a worldwide attention to develop the system to meet this temperature.Conventional cascade vapour compression refrigerators are normally used for providing refrigeration below 230K. Generally, two cascade stages are required for temperatures down to 200K and three stages for temperatures down to 173K. As the number of stages increase, the complexity of the system, number of heat exchangers and compressors, and ultimately cost increases. Alternatively, it is also possible to use single stage refrigeration system that operates with a mixture of refrigerants to provide refrigeration at low temperatures. Such systems are known as Mixed Refrigerant Cascade (MRC) systems, or Auto Refrigerant Cascade (ARC)system.The use of a single compressor (used in domestic refrigerators and air conditioners) in a MRC refrigeration system compared to multiple compressors in cascade vapour compression refrigerator results in reduction of cost and complexity, and increases reliability.

Atsiliepimai

  • Atsiliepimų nėra
0 pirkėjai įvertino šią prekę.
5
0%
4
0%
3
0%
2
0%
1
0%
(rodomas nebus)