The measurement of the temporal and spatial distribution of a suppression agent is essential for characterizing the fire extinguishment process and for certifying a fire-suppression system. A time response of 10 ms to 50 ms is required for dry-bay suppression studies and 100 ms to 200 ms for ground-vehicle crew compartment deflagration protection. The Differential Infrared Rapid Agent Concentration Sensor (DIRRACS) is being developed to provide such measurements. The first version of the instru…
The measurement of the temporal and spatial distribution of a suppression agent is essential for characterizing the fire extinguishment process and for certifying a fire-suppression system. A time response of 10 ms to 50 ms is required for dry-bay suppression studies and 100 ms to 200 ms for ground-vehicle crew compartment deflagration protection. The Differential Infrared Rapid Agent Concentration Sensor (DIRRACS) is being developed to provide such measurements. The first version of the instrument consisted of an infrared (IR) source, narrowband pass filter, chopper, and pyroelectric sensor. While the device was capable of providing qualitative data as fast as 30 ms, the device was affected by air flow and had low signal-to-noise ratio and a too-slow time response.
Knygos.lt nariams
20,29 €
-30%
Įprastai
28,99 €
Kaina registruotiems pirkėjams
Prisijunkite ir už šią prekę gausite 0,29 Knygų Eurų!?
The measurement of the temporal and spatial distribution of a suppression agent is essential for characterizing the fire extinguishment process and for certifying a fire-suppression system. A time response of 10 ms to 50 ms is required for dry-bay suppression studies and 100 ms to 200 ms for ground-vehicle crew compartment deflagration protection. The Differential Infrared Rapid Agent Concentration Sensor (DIRRACS) is being developed to provide such measurements. The first version of the instrument consisted of an infrared (IR) source, narrowband pass filter, chopper, and pyroelectric sensor. While the device was capable of providing qualitative data as fast as 30 ms, the device was affected by air flow and had low signal-to-noise ratio and a too-slow time response.
Atsiliepimai
Atsiliepimų nėra
0 pirkėjai įvertino šią prekę.
5
0%
4
0%
3
0%
2
0%
1
0%
Kainos garantija
Ženkliuku „Kainos garantija” pažymėtoms prekėms Knygos.lt garantuoja geriausią kainą. Jei identiška prekė kitoje internetinėje parduotuvėje kainuoja mažiau - kompensuojame kainų skirtumą. Kainos lyginamos su knygos.lt nurodytų parduotuvių sąrašu prekių kainomis. Knygos.lt įsipareigoja kompensuoti kainų skirtumą pirkėjui, kuris kreipėsi „Kainos garantijos” taisyklėse nurodytomis sąlygomis. Sužinoti daugiau
Elektroninė knyga
22,39 €
DĖMESIO!
Ši knyga pateikiama ACSM formatu. Jis nėra tinkamas įprastoms skaityklėms, kurios palaiko EPUB ar MOBI formato el. knygas.
Svarbu! Nėra galimybės siųstis el. knygų jungiantis iš Jungtinės Karalystės.
Tai knyga, kurią parduoda privatus žmogus. Kai apmokėsite užsakymą, jį per 7 d. išsiųs knygos pardavėjas . Jei to pardavėjas nepadarys laiku, pinigai jums bus grąžinti automatiškai.
Šios knygos būklė nėra įvertinta knygos.lt ekspertų, todėl visa atsakomybė už nurodytą knygos kokybę priklauso pardavėjui.
Perskaityta knyga:
Nenauja knyga, kuri parduodama tiesiai iš knygos.lt sandėlio. Knygos kokybė įvertinta knygos.lt ekspertų.
Tai knyga, kurią parduoda privatus žmogus. Kai apmokėsite užsakymą, jį per 7 d. išsiųs knygos pardavėjas . Jei to pardavėjas nepadarys laiku, pinigai jums bus grąžinti automatiškai.
Šios knygos būklė nėra įvertinta knygos.lt ekspertų, todėl visa atsakomybė už nurodytą knygos kokybę priklauso pardavėjui.
Atsiliepimai