Research Paper (postgraduate) from the year 2008 in the subject Medicine - Dentistry, University of Mosul (Dental college), language: English, abstract: Aims: To evaluate the degree of change that may occur in reconditioning the titanium bracket via micro- etcher. Materials and Methods: The sample consisted of (10) pure titanium brackets for each of control and reconditioning brackets. The parameters of the reconditioned bracket (slot width, slot depth, inter-wing gap, labio-lingual angle and b…

Reconditioning of Debonded Pure Titanium Bracket (Using Micro-etcher) (el. knyga) (skaityta knyga) | knygos.lt

Atsiliepimai

Formatai:

9,49 € El. knyga

Aprašymas

Research Paper (postgraduate) from the year 2008 in the subject Medicine - Dentistry, University of Mosul (Dental college), language: English, abstract: Aims: To evaluate the degree of change that may occur in reconditioning the titanium bracket via micro- etcher. Materials and Methods: The sample consisted of (10) pure titanium brackets for each of control and reconditioning brackets. The parameters of the reconditioned bracket (slot width, slot depth, inter-wing gap, labio-lingual angle and base curvature angle) were measured and compared with that of the control bracket. Results: The results showed no significant difference between the control and reconditioned brackets of the slot parameters (width, depth, inter-win gap, labio-lingual angle) and the bracket's base curvature angle. While, the tensile bond strength of the control brackets showed significantly higher mean value as compared with the recycled group. Conclusions: The reconditioning of pure titanium brackets is recommended for reuse in the orthodontic treatment after sterilization

9,49 €
Prisijunkite ir už šią prekę
gausite
0,09 Knygų Eurų! ?

Elektroninė knyga:
Atsiuntimas po užsakymo akimirksniu! Skirta skaitymui tik kompiuteryje, planšetėje ar kitame elektroniniame įrenginyje.

Mažiausia kaina per 30 dienų: 9,49 €

Mažiausia kaina užfiksuota: Kaina nesikeitė


Research Paper (postgraduate) from the year 2008 in the subject Medicine - Dentistry, University of Mosul (Dental college), language: English, abstract: Aims: To evaluate the degree of change that may occur in reconditioning the titanium bracket via micro- etcher. Materials and Methods: The sample consisted of (10) pure titanium brackets for each of control and reconditioning brackets. The parameters of the reconditioned bracket (slot width, slot depth, inter-wing gap, labio-lingual angle and base curvature angle) were measured and compared with that of the control bracket. Results: The results showed no significant difference between the control and reconditioned brackets of the slot parameters (width, depth, inter-win gap, labio-lingual angle) and the bracket's base curvature angle. While, the tensile bond strength of the control brackets showed significantly higher mean value as compared with the recycled group. Conclusions: The reconditioning of pure titanium brackets is recommended for reuse in the orthodontic treatment after sterilization

Atsiliepimai

  • Atsiliepimų nėra
0 pirkėjai įvertino šią prekę.
5
0%
4
0%
3
0%
2
0%
1
0%
(rodomas nebus)